Commissioning (software)
6.10 Linking an additional encoder (optional)
SIMOTION D4x5-2
248 Commissioning and Hardware Installation Manual, 02/2012
6.10 Linking an additional encoder (optional)
6.10.1 Basic principles
Using encoders
In addition to a motor encoder, additional encoders can be linked and configured:
Additional encoders on the drive
Encoders with DRIVE-CLiQ interface
Encoders connected to a CU310/CU310-2 or CUA32 via the onboard encoder
interface
Encoders connected to SIMOTION D via an SMx module
Additional encoders on SIMOTION D
Encoders connected via PROFIBUS
Encoders connected via PROFINET
Configuring additional encoders
The additional encoder can be used in SIMOTION, for example, as:
Machine encoder (second encoder = direct measuring system)
A direct measuring system measures the technological parameter directly, i.e. without the
interference of influences such as torsion, backlash, slip, etc. This can facilitate improved
smoothing of mechanical influences by means of the closed-loop control. If you use a
second encoder as a machine encoder, you can work with the encoder changeover
function.
External encoder
You can use the external encoder to record an external master value, for example.
Encoder for hydraulic axes
Encoders for the implementation of cam controllers