Loading...
Connecting
3.5 Connecting DRIVE-CLiQ components
SIMOTION D4x5-2
52 Commissioning and Hardware Installation Manual, 02/2012
3.5 Connecting DRIVE-CLiQ components
3.5.1 DRIVE-CLiQ wiring
Introduction
The components of the SINAMICS S120 drive family and the SIMOTION D4x5-2 with
CX32-2 are wired together by means of DRIVE-CLiQ. DRIVE-CLiQ is a communication
system that enables the SIMOTION D4x5-2 to detect the connected components
automatically. It provides a wiring tree whose topology can be visualized in
SIMOTION SCOUT.
Note
For information on the number of DRIVE-CLiQ interfaces and their properties, refer to the
SIMOTION D4x5-2
Manual.
Rules for the DRIVE-CLiQ wiring
The following rules must be followed for DRIVE-CLiQ wiring:
Ring wiring is not permitted
Components must not be double-wired
For a motor module, the power line for the motor and the associated motor encoder must
be connected.
Further information on DRIVE-CLiQ wiring can be found
In the
SINAMICS S120
Function Manual, Section
Rules for wiring with DRIVE-CLiQ
In the
SINAMICS S120 Control Units and Supplementary System Components
Manual