Commissioning (software)
6.13 Configuration of the technology objects and I/O variables
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 02/2012
265
Procedure
To achieve the best possible output cam resolution on the onboard I/Os of a SIMOTION
D4x5-2, activate the output and select "Cam output on cam output (CAM)".
Then assign a hardware output. To do this, open the Assignment dialog box via
and
select a free (i.e. not yet used) I/O.
Note
Only those I/Os are displayed that have the appropriate output cam functionality (CAM_xx
[channel name, terminal number]). If no suitable I/Os are displayed, you must first configure
the I/Os (I/O must be configured as "output cam (CAM)")
Figure 6-54 Configuration of an output cam for the D4x5-2
A maximum of two edges can be output per processing cycle clock of TO outputCam or TO
camTrack.
Detailed information on the configuration of the TO outputCam / TO camTrack can be found
in the
SIMOTION Output Cams and Measuring Inputs
Function Manual.