Commissioning (software)
6.22 Migration of SIMOTION D4x5 to SIMOTION D4x5-2
SIMOTION D4x5-2
302 Commissioning and Hardware Installation Manual, 02/2012
Table 6- 19 Transfer of existing projects from D4x5 to D4x5-2
Keyword Explanation
PROFINET interface D4x5 with CBE30 (4 ports) is mapped on D4x5-2 DP/PN onboard PROFINET interface
(3 ports):
Only the wiring of ports 1 to 3 are taken over
Components on port 4 have to be reconnected
Communication relations, I/O data, synchronous operation connections, data exchange
broadcast data, module addresses and diagnostics addresses are retained
Any existing PG/PC assignment is taken over
Mapping of D4x5 on D4x5-2:
X1400 (P1, P2, P3, not P4) → X150 (P1, P2, P3)
PROFIBUS interfaces The configurations on the PROFIBUS interfaces including any existing PG/PC assignment
are retained.
Mapping of D4x5 on D4x5-2:
X126 DP1 → X126 DP
X136 DP2/MPI → X136 DP/MPI
Reduction ratio of
PROFIBUS cycle clock to
position control cycle clock
As of SIMOTION V4.3, the SIMOTION D4x5-2 supports reduction ratio of PROFIBUS cycle
clock to position control cycle clock.
The following applies for V4.2: PROFIBUS cycle clock: Position control cycle clock = 1: 1
If SIMOTION D4x5 projects have been transferred in which a reduction ratio factor was set,
A SIMOTION version ≥ V4.3 must be used, or
The cycle clock setting must be adapted for V4.2 projects