EasyManua.ls Logo

Siemens SIMOTION D425-2

Siemens SIMOTION D425-2
394 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostics
8.1 Diagnostics via LED displays
SIMOTION D4x5-2
350 Commissioning and Hardware Installation Manual, 02/2012
Meaning LED display
RDY RUN STOP SU/PF SF DP DP/MPI PN SY/MT OPT
Upgrade/downgrade of
DRIVE-CLiQ components running
0.5/1
(yellow)
x x x x x x x x x
The upgrade/downgrade of
DRIVE-CLiQ components is
completed (power OFF/ON of the
upgraded/downgraded devices is
necessary)
2/1
(yellow)
x x x x x x x x x
PROFIBUS DP interfaces as master
No parameter assignment
available
x x x x x 0 0 x x x
At least one slave is missing x x x x x 1
(red)
1
(red)
x x x
Bus status "Clear" x x x x x 0.5/1
(green)
0.5/1
(green)
x x x
Bus status "Operate" x x x x x 1
(green)
1
(green)
x x x
PROFIBUS DP interfaces as i-slave
No parameter assignment
available
x x x x x 0 0 x x x
No parameter assignment master
available
x x x x x 1
(red)
1
(red)
x x x
Bus status "Clear" x x x x x 0.5/1
(green)
0.5/1
(green)
x x x
Bus status "Operate" x x x x x 1
(green)
1
(green)
x x x
Upgrading SIMOTION devices (device update tool)
Upgrade/downgrade running x x x x 0.5/1
(green)
x x x x x
Upgrade/downgrade completed
with error
x x x x Λ
(red)
x x x x x
Upgrade/downgrade completed
without error
4)
x x x x 0
5)
x x x x x
Upgrade data is being copied from
USB stick to CompactFlash card
0.5/1
(yellow/
green)
x x x x x x x x x
Booting is not possible from the
used USB stick
0.5/1
(yellow)
min.
10 s
x x x x x x x x x
Upgrade data copying from USB
stick to CompactFlash card
completed with error
Λ
(red)
x x x x x x x x x
Upgrade data copying from USB
stick to CompactFlash card
completed without error
1
(green),
min.
10 s
2)
x x x x x x x x x

Table of Contents

Other manuals for Siemens SIMOTION D425-2