10.99 Faults and Alarms
Siemens AG 6SE7087-6KP50
SIMOVERT MASTERDRIVES Operating Instructions 12-23
Number / Alarm Cause Counter-measure
A148
Deceleration = 0
The current deceleration value is 0, e.g.
because of a RAM storage error or an error in
the technology firmware.
Effect:
The position control system is deactivated and
the drive is decelerated via the "deceleration
time during errors" (machine data 43).
This fault should not normally occur. It is used
as an emergency stop feature for the
technology software.
Replace the hardware (M7; MCT).
A149
Distance to go negative
Internal error in the technology software.
Effect:
The position control system is deactivated and
the drive is decelerated via the "deceleration
time during errors" (machine data 43).
This fault should not normally occur. It is used
as an emergency stop feature for the
technology software.
A150
Slave axis already
allocated to other
master axis
The selected NC program contains a slave
axis which is already being used by another
master axis (M7 only, not significant for the
F01 technology option).
Example:
NC program 1, started in axis X, contains NC
blocks for axes X and Y. NC program 2 is
started in axis Z and contains NC blocks for
axes Z and Y. This program is denied with
warning 150, because axis Y is already being
used by program 1.
Effect:
NC program execution is inhibited or aborted.
The same slave axis cannot be used
simultaneously by several NC programs.
A151
Slave axis operating
mode not allowed
The slave axis required by the master axis is
not in "slave" mode (M7 only, not significant
for the F01 technology option).
Effect:
NC program execution is inhibited or aborted,
the axis is brought to a standstill via the
deceleration ramp.
The slave axis must be switched to "slave"
mode.
A152
Slave axis operating
mode changed
The "slave" mode was deselected in the slave
axis during the traversing movement (M7 only,
not significant for the F01 technology option).
Effect:
NC program execution is inhibited or aborted,
the axis is brought to a standstill via the
deceleration ramp.
The slave axis must remain switched to
"slave" mode.
A153
Error in slave axis
A warning is active in the slave axis required
by the master axis (M7 only, not significant for
the F01 technology option).
Effect:
NC program execution is inhibited or aborted,
the axis is brought to a standstill via the
deceleration ramp.
The NC program will only run if all of the axes
it needs are error-free. To clear this warning,
you must first clear all the warnings in the
slave axis.
A154
Follow-up mode in
slave axis active
The "follow-up mode" [FUM] control signal is
active in the slave axis required by the master
axis. A slave axis which is switched to follow-
up mode cannot be operated by the master
axis (M7 only, not significant for the F01
technology option).
Effect:
NC program execution is inhibited or aborted,
the axis is brought to a standstill via the
deceleration ramp.
Deactivate follow-up mode in the slave axis.

Other manuals for Siemens simovert masterdrives

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simovert masterdrives and is the answer not in the manual?

Siemens simovert masterdrives Specifications

General IconGeneral
BrandSiemens
Modelsimovert masterdrives
CategoryDC Drives
LanguageEnglish

Related product manuals