10.99 Faults and Alarms
Siemens AG 6SE7087-6KP50
SIMOVERT MASTERDRIVES Operating Instructions 12-31
Number / Alarm Cause Counter-measure
A216
Multiple block transition
not allowed
The decoded NC block contains several
mutually exclusive G functions from the block
transition group (G60, G64, G66, G67).
Example:
N1 G64 G66 X1.000 FX100.00
The NC program number and NC block
number in which the NC block decoder
detected the error can be read out with the
"output actual values - decoder error location"
task.
Effect:
NC program execution is inhibited or aborted,
the axis is brought to a standstill via the
deceleration ramp.
Correct the NC block.
A217
Multiple axis
programming not
allowed
The decoded NC block contains the same axis
more than once.
Example:
N1 G90 G01 X100.000 X200.000 F100.00
The NC program number and NC block
number in which the NC block decoder
detected the error can be read out with the
"output actual values - decoder error location"
task.
Effect:
NC program execution is inhibited or aborted,
the axis is brought to a standstill via the
deceleration ramp.
Correct the NC block.
A218
Multiple path condition
not allowed
The decoded NC block contains several
mutually exclusive G functions from the
preparatory function group
(G00/G01/G76/G77).
Example:
N1 G01 (linear interpolation) G77 (chaining)
X10 F100.
The NC program number and NC block
number in which the NC block decoder
detected the error can be read out with the
"output actual values - decoder error location"
task.
Effect:
NC program execution is inhibited or aborted,
the axis is brought to a standstill via the
deceleration ramp.
Correct the NC block.
A219
Multiple dimensions
specification not
allowed
The decoded NC block contains several
mutually exclusive G functions from the
dimensional notation group (G90/G91).
Example:
N1 G90 G91.
The NC program number and NC block
number in which the NC block decoder
detected the error can be read out with the
"output actual values - decoder error location"
task.
Effect:
NC program execution is inhibited or aborted,
the axis is brought to a standstill via the
deceleration ramp.
Correct the NC block.

Other manuals for Siemens simovert masterdrives

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simovert masterdrives and is the answer not in the manual?

Siemens simovert masterdrives Specifications

General IconGeneral
BrandSiemens
Modelsimovert masterdrives
CategoryDC Drives
LanguageEnglish

Related product manuals