EasyManua.ls Logo

Siemens SINAMICS CU240S DP-F - Page 134

Siemens SINAMICS CU240S DP-F
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Communication
6.2 Cyclic Communication
Control Units CU240S
134 Operating Instructions, 07/2008 - FW 3.2, A5E00766042B AD
Table 6-14 Switch over behavior of telegram structures, Part 5
P0922 = 353 → 20
if P0700 =
353 → 350
if P0700 =
353 → 352/354
if P0700 =
353 → 999/1
if P0700 =
1, 2 4 6 1, 2, 4 6 1, 2, 4 6 1, 2, 4 6
P0820 = no change 2013.15 2090.15
8890.15
no change 2091.4
8891.4
no change no change no change no change
P0821 = no change no change no change no change 2091.5
8891.5
no change no change no change no change
P1035 = 19.13 19.13 19.13 no change 2090.13
8890.13
no change 2090.13
8890.13
no change no change
P1036 = 19.14 19.14 19.14 no change 2090.14
8890.14
no change 2090.14
8890.14
no change no change
Table 6-15 Switch over behavior of telegram structures, Part 6
P0922 = 354 → 1/353
if P0700 =
354 → 20
if P0700 =
354 → 350
if P0700 =
354 → 999/352
if P0700 =
1, 2, 4 6 1, 2 4 6 1, 2, 4 6 1, 2, 4 6
P0820 = 0.0 0.0 no change 2013.15 2090.15
8890.15
no change 2091.4
8891.4
no change no change
P0821 = no change no change no change no change no change no change 2091.5
8891.5
no change no change
P1035 = no change 2090.13
8890.13
19.13 19.13 19.13 no change 2090.13
8890.13
no change no change
P1036 = no change 2090.14
8890.14
19.14 19.14 19.14 no change 2090.14
8890.14
no change no change
Table 6-16 Switch over behavior of telegram structures, Part 7
P0922 = 999 → 1/353
if P0700 =
999 → 20
if P0700 =
999 → 350
if P0700 =
999 → 352/354
if P0700 =
1, 2, 4 6 1, 2 4 6 1, 2, 4 6 1, 2, 4 6
P0820 = 0.0 0.0 no change 2013.15 2090.15
8890.15
no change 2091.4
8891.4
0.0 0.0
P0821 = 0.0 0.0
1)
0.0 0.0
1)
0.0
1)
no change 2091.5
8891.5
0.0 0.0
1)
P1035 = no change 2090.13
8890.13
19.13 19.13 19.13 no change 2090.13
8890.13
no change 2090.13
8890.13
P1036 = no change 2090.14
8890.14
19.14 19.14 19.14 no change 2090.14
8890.14
no change 2090.14
8890.14
1) This value is set, if you have switched from 350 to 999 before. Otherwise the value won't change.