EasyManua.ls Logo

Siemens SINAMICS G120P CU230P-2 User Manual

Siemens SINAMICS G120P CU230P-2
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
___________________
___________________
___________________
___________________
___________________
SINAMICS
SINAMICS G120P
CU230P-2 Control Units
Compact Operating Instructions
Edition 01/2017
01/2017
A5E38815802B AA
Fundamental safety
instructions
1
Scope of delivery
2
Installing
3
Commissioning
4
More information
5
Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120P CU230P-2 and is the answer not in the manual?

Siemens SINAMICS G120P CU230P-2 Specifications

General IconGeneral
Control Unit TypeCU230P-2
ApplicationPumps, Fans, Compressors
Digital Inputs6
Analog Inputs2
Digital Outputs3
Analog Outputs2
Safety IntegratedSTO (Safe Torque Off)
Degree of ProtectionIP20
Input Voltage24 V DC
Supply Voltage24 V DC
Communication InterfacesPROFIBUS, USS, Modbus RTU
Operating Temperature-10 to +50 °C
Storage Temperature-40 to +70 °C
Relative Humidity5% to 95% (non-condensing)
AltitudeUp to 2000 m without derating

Summary

Fundamental Safety Instructions

General Safety Instructions

Provides essential safety warnings and instructions for safe operation and to prevent hazards.

Industrial Security

Outlines measures to protect plants, systems, machines, and networks against cyber threats.

Scope of Delivery

Installing

Plugging Control Unit onto Power Module

Instructions for plugging the Control Unit onto the Power Module and special features for different modules.

Overview of Interfaces

Details the interfaces at the front and lower side of the Control Unit, including slots, terminals, and LEDs.

Terminal Strips

Explains terminal strips with wiring examples and electrical connections for inputs and outputs.

Factory Interface Settings

Describes the default interface configurations for PROFIBUS, PROFINET, and USS interfaces.

Default Interface Settings

Details various default settings for digital and analog inputs/outputs and fieldbus interfaces.

Commissioning

Commissioning Tools

Lists operator panels (IOP, BOP-2) and PC tools (STARTER, Startdrive) for inverter commissioning.

BOP-2 Operator Panel Commissioning

Guides through using the BOP-2 panel for quick commissioning, motor data identification, and optimization.

Fieldbus Connection

Covers connecting the inverter to fieldbuses like PROFINET, PROFIBUS, Modbus RTU, and BACnet MS/TP.

Frequently Required Parameters

Lists and explains commonly used parameters for configuring the inverter's functions.

More Information

Manuals Overview

Lists available manuals for CU230P-2, including operating instructions and function manuals.

Technical Support

Provides contact information for technical support and links to product support resources.