Troubleshooting
8.3 Troubleshooting with the BOP
Control Units CU240S
Operating Instructions, 07/2008 - FW 3.2, A5E00766042B AD
199
Motor failure without fault or warning message
If the motor fails to start when the ON command has been given:
Check that P0010 = 0.
Check the inverter state via r0052.
Check command and setpoint source (P0700 and P1000).
Check, if the motor data relate to the inverter data power range and voltage.
Note
For troubleshooting, pay regard to the "Installation Check List" in the chapter "Installation"
of this manual.