1 Alarms 11.02
1-52
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Check hardware.
Program Continuation: Switch control OFF - ON.
4291 Module in local P-bus slot %1 error codes %2 %3 %4 %2 %3 %4
Parameters: %1 = Slot number
%2 = Error code
%3 = Error code
%4 = Error code
Definitions: The module on the specified slot has signaled a diagnostics alarm. The error code
reported corresponds to the AS300 documentation.
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Check hardware.
Program Continuation: Switch control OFF - ON.
4300 Declaration in MD %1 is not allowed for geometry axis/spindle %2.
Parameters: %1 = String: MD identifier
%2 = Axis name, spindle number
Definitions: Geometry axes and spindles cannot be operated as concurrent positioning axes.
Reactions: - NC not ready.
- Mode group not ready, also effective for single axes
- NC Stop on alarm.
- NC Start disable in this channel.
- Alarm display.
- Interface signals are set.
Remedy: Please inform the authorized personnel/service department. Reset MD 30450
IS_CONCURRENT_POS_AX for the axis concerned.
Program Continuation: Switch control OFF - ON.
4310 Declaration in MD %1 index %2 is not allowed.
Parameters: %1 = String: MD identifier
%2 = Index in MD array
Definitions: The machine data values must be written in the array in ascending order.
Reactions: - Mode group not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- Alarm display.
- Interface signals are set.
Remedy: Please inform the authorized personnel/service department. Correct the MD.
Program Continuation: Clear alarm with the RESET key in all channels of this mode group. Restart part program.