1-53
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
11.02 1 Alarms
4320 Axis %1 function %2 %3 and %4 not allowed
Parameters: %1 = String: Axis identifier
%2 = String: MD identifier
%3 = String: Bit
%4 = String: MD identifier
Definitions: The functions declared by the specified machine data cannot simultaneously be active for
one axis.
Reactions: - Mode group not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- Alarm display.
- Interface signals are set.
Remedy: Deactivate one of the functions.
Program Continuation: Switch control OFF - ON.
4334 Channel %1 The amount of fine correction in parameter %2 of the orientable tool-
holder %3 is too large
Parameters: %1 = Channel number
%2 = Invalid parameter of the orientable toolholder
%3 = Number of the orientable toolholder
Definitions: The maximum permissible value of the fine correction in an orientable toolholder is limited
by the machine data $MC_TOCARR_FINE_LIM_LIN for linear variables, and by the
machine data $MC_TOCARR_FINE_LIM_ROT for rotary variables. The alarm can only
occur if the setting data $SC_TOCARR_FINE_CORRECTION is not equal to zero.
Reactions: - Alarm display.
- Interface signals are set.
- Correction block is reorganized.
- NC Stop on alarm at block end.
Remedy: Enter a valid fine correction value.
Program Continuation: Clear alarm with the RESET key. Restart part program
4336 Channel %1 orientable toolholder no. %2 for orientation transformation %3 does
not exist
Parameters: %1 = Channel number
%2 = Number of the orientable toolholder
%3 = Number of the orientation transformation that is to be parameterized with the orient-
able toolholder
Definitions: The orientable toolholder, with whose data the orientation transformation is to be parame-
terized (see machine data $MC_TRAFO5_TCARR_NO_1/2), does not exist.
Reactions: - Alarm display.
- Interface signals are set.
- Correction block is reorganized.
- NC Stop on alarm at block end.
Remedy: Enter a valid tool-carrier number.