1 Alarms 11.02
1-54
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
4338 Channel %1 invalid transformation type '%2' in toolholder %3 for orientation trans-
former %4
Parameters: %1 = Channel number
%2 = Transformer type
%3 = Number of the orientable toolholder
%4 = Number of the orientation transformation that is to be parameterized with the orient-
able toolholder
Definitions: The parameters of the orientation transformation are taken over from the data of an ori-
entable toolholder. This orientable toolholder contains an invalid transformation type.
(Types T, P and M are permissible).
Reactions: - Alarm display.
- Interface signals are set.
- Correction block is reorganized.
- NC Stop on alarm at block end.
Remedy: Enter a valid transformation type.
Program Continuation: Clear alarm with the RESET key. Restart part program
4340 Channel %1 block %2 invalid transformation type in transformation no. %3
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Transformation number
Definitions: An invalid, i.e. undefined, number was entered in one of the machine data
TRAFO_TYPE_1 ... TRAFO_TYPE_8. This alarm also occurs if a certain type of transfor-
mation is only impossible on the type of control used (e.g. 5-axis transformation on a
SINUMERIK 802D).
Reactions: - Alarm display.
- Interface signals are set.
- Correction block is reorganized.
- NC Stop on alarm at block end.
Remedy: Enter a valid transformation type.
Program Continuation: Clear alarm with the RESET key. Restart part program
4341 Channel %1 block %2 no data set available for transformation no. %3
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Transformation number
Definitions: Only a limited number of machine data sets (usually 2) is available for each related group
of transformations (e.g. orientation transformations, Transmit, Tracyl, etc.). This alarm is
output if an attempt is made to set more transformations from a group.
Example:
Two orientation transformations are allowed. The machine data contains e.g.:
TRAFO_TYPE_1 = 16 ; 1st orientation transformation
TRAFO_TYPE_2 = 33 ; 2nd orientation transformation
TRAFO_TYPE_3 = 256 ; 1st transmit transformation
TRAFO_TYPE_4 = 20 ; 3rd orientation transformation ==> This entry triggers alarm
Reactions: - Alarm display.
- Interface signals are set.
- Correction block is reorganized.
- NC Stop on alarm at block end.
Remedy: Enter valid machine data.
Program Continuation: Clear alarm with the RESET key. Restart part program