11.2.3 Description of alarms
111 001
Non-interpretable step in line %1
Explanation %1 = Line number
The step is not an element of ManualTurn.
Reaction Alarm display
EasyStep sequence is not loaded
Remedy Delete program step or edit program in operating area PROGRAMS of
SINUMERIK 840D or 810D (CNC mode).
111 002
Not enough memory
Abort in line %1
Explanation %1 = Line number
EasyStep sequence contains too many steps
Reaction Alarm display
EasyStep sequence is not loaded
Remedy Edit the program in the PROGRAMS operating area of the
SINUMERIK 840D or 810D (CNC mode).
111 003
ManualTurn: %1
Explanation %1 = Error number
Internal system message via the user interface of ManualTurn
Reaction Alarm display
Remedy Acknowledge error and inform Siemens.
111 004
File does not exist or is incorrect: %1
Explanation %1 = Name of the file/contour
EasyStep sequence cannot interpret a step with contour programming.
Contour does not exist in directory.
Reaction Alarm display
NC start disable
Remedy Load contour in directory.
111 005
Error on interpreting the contour %1
Explanation %1 = Name of the contour
Contour is incorrect
Reaction Alarm display
NC start disable
Remedy Check machining sequence of contour
111 006
Maximum number of contour elements exceeded %1
Explanation %1 = Name of the contour
Max. permissible number of 50 contour elements exceeded during
interpretation of machining sequence of a contour.
Reaction Alarm display