9 
 
08/2005  Program Management
9.2 Mana
in
 
ro
rams with Sho
Turn on NCU 
HMI Embedded
 
9
 
♥ Siemens AG, 2005. All rights reserved 
SINUMERIK 840D sl Operation/Programming ShopTurn (BAT) – 08/2005 Edition  9-385 
 
 
  Press the "OK" softkey. 
The tool/zero point data will be set up in the same directory in which 
the selected program is stored. 
If a tool/zero point file with the specified name already exists, this will 
now be overwritten with the new data. 
    If an MPF program and an INI file of the same name are located in a 
directory, the INI file will be automatically started when the MPF 
program is selected. In this way, unwanted tool data can be changed.
    
 
Importing data 
 
 
Continue
                >
 
  Open the Program Manager. 
  Place the cursor on the tool/zero point data backup that you wish 
to re-import. 
 
Execute 
 -or-   
  Select the "Execute" softkey or the "Input" key. 
The window "Read in backup data" is opened. 
     Select the data (tool offset data, magazine loading data, zero 
point data, basic work offsets) that you wish to read in. 
 
 
  Press the "OK" softkey. 
The data are read in.  
Depending on which data you have selected, ShopTurn behaves as 
follows: 
 
  All tool offset data 
All data in the tool management system is deleted first. The backup 
data is then read in. 
All tool offset data used in the program 
If at least one of the tools to be read in already exists in the tool 
management system, you can choose between the following options. 
 
Replace all 
 
  Select the "Replace all" softkey to import all tool data. Any existing 
tools will now be overwritten without a warning prompt. 
-or- 
 
Replace 
none 
 
  Select the "Replace none" softkey if you want to cancel the data 
import. 
-or-