4 active TCU connected in parallel to PCU
To operate a machine with more operating stations then the maximum number the 
displacement mechanism ensures that only the permitted number of TCUs are active in 
shadowing grouping. The remaining TCUs are switched to a passive mode, which means 
they no longer represent a load relative to the resources. Thus the number of TCUs that can 
be connected to one HMI application is practically no longer limited, the limitation is the 
number of concurrently active TCUs.
Conguration
There are two new entries in the cong.ini le for a TCU for the displacement mechanism:
• SUSPENDLOCK: controls whether the TCU can be displaced via the displacement 
mechanism.
SUSPENDLOCK = 0 means that a displacement disable is not set (preset), i.e. the TCU may be 
displaced by any other TCU. 
SUSPENDLOCK=1 means that this TCU can never be displaced. 
• SUSPENDPRIORITY: This entry species a priority for the displacement mechanism to the 
TCU. In a displacement process the TCUs among the active TCUs with the lowest priority that 
do not have a displacement disable will displaced. The priority is specied as numeric value 
in the range 1 - 10.
The preset is 1 (lowest priority).
Note
If you set a displacement disable for a TCU then specication of a displacement priority is 
unnecessary because it never is used due to the displacement disable. 
Displacement rules
The TCU can assume the following states:
• The TCU is active and has user authorization: This can be identied as the TCU shows the 
screen of the operating software and the screen is bright.
• The TCU is active, however, in the monitoring mode (i.e. it presently has no user 
authorization): This can be identied as the TCU shows the screen of the operating software, 
however, it is darkened in comparison to the TCU with user authorization.
• The TCU is passive: The TCU shows the selection menu of the possible connections instead 
of a screen of the operating software, and the softkey for selection of the last active 
connection of the TCU is shown in color.
When a TCU boots, the TCU always attempts to establish the rst connection specied in 
its cong le. The TCUs from a shadowing group establish their specied connection one 
after the other as long as the maximum number of permissible active operator units is not 
exceeded. 
If a TCU encounters the situation that this number is already reached in its power up, then 
it attempts to obtain a connection via the displacement mechanism. If it can displace a 
formerly active operator unit then it takes on the active status itself, otherwise it transitions 
to passive status immediately after booting.
General information and networking
4.3Networking
Handheld Terminal HT 8
Equipment Manual, 02/2024, A5E52918633B AA 73