The computer to be monitored must be con󹪝gured in the con󹪝g.ini con󹪝guration 󹪝le of the
TCU according to the general con󹪝guration for a TCU in a separate host section as a
switchover target for this TCU.
Where necessary, a password has to be speci󹪝ed in the con󹪝guration, if the VNC server
requires one on the target system (see below).
To ensure that the TCU recognizes the new switchover target, the TCU requires a restart and
reboot.
The screen resolution of the computer to be monitored must be adjusted to the conditions
of the TCU, since otherwise the TCU scales the image received to its possible range of
representation, which would adversely a󹪜ect the representation on the TCU.
Con󹪝guration
1&8
7&8
6\VWHPQHWZRUN
1HWZRUN
3*3&
;
;
Figure4-21 Con󹪝guration example
Con󹪝guration
The con󹪝g.ini 󹪝le is located in the following directory:
NCU: /user/common/tcu/<TCU name>/common/tcu
PCU (WindowsXP): F:\user_base\common\tcu\<TCU name>\common\tcu
PCU (Windows7): C:\ProgramData\Siemens\MotionControl\user\common\t
cu\<TCU name>\common\tcu
The con󹪝g.ini 󹪝le must be stored on the boot server (active DHCP).
Example:
[Station]
General information and networking
4.3Networking
Handheld Terminal HT 8
84 Equipment Manual, 02/2024, A5E52918633B AA