5 Configuring 11.92
5.24 FX 8 Presetting of tool size via EPROM
Program example with unconditional call
The tool size is to be preset in magazine 1 with FX 8: WZ-GR:EP. The data for the tool size
are stored on the EPROM in DB 100 from DW0. The function is started via input I 3.0. Output
"F" is set when no presetting is permitted, i.e. when one of the errors described above (3 - 7)
has occurred.
: A I 3.0 Edge for start
: AN F 104.2 Process ended
: S F 104.1 Process running
:
: L KB 1 Magazine number 1
: T FY 100
: L KB 100 DB 100
: T FY 101
: L KB 0
: T FW 102 1st Dw in DB EPROM
:DO FX 8
NAME : WZ-GR:EP
ST : F 104.1 Start signal
MANR : FY 100 Fictitious magazine
DBEP : FY 101 DB 100
DW-M : FW 102 1st DW in DB EPROM
VG-L : F 104.1 Process running
VG-B : F 104.2 Process ended
F : F 104.3 Error message
:
:BE
Note:
The start edge I 3.0 must be reset on "process ended" at the latest, otherwise a new start is
initiated.