Loading...
11.92 5 Configuring
5.24 FX 8 Presetting of tool size via EPROM
Program example with conditional call
: A I 3.0 Edge for start
: AN F 104.2 Process ended
: S F 104.1 Process running
:
: L KB 1 Magazine number 1
: T FY 100
: L KB 100 DB 100
: T FY 101
: L KB 0
: T FW 102 1st DW in DB EPROM
:
: O F 104.1 Start signal
: O F 104.2 Process ended
: DOC FX 8
NAME : WZ-GR : EP
ST : F 104.1 Start signal
MANR : FY 100 Fictitious magazine
DBEP : FY 101 DB 100
DW-M : FW 102 1st DW in DB EPROM
VG-L : F 104.1 Process running
VG-B : F 104.2 Process ended
F : F 104.3 Error message
:
:BE
Note:
The start edge I 3.0 must be reset on "process ended" at the latest, otherwise a new start is
initiated.
In the case of a conditional call, first the "initial setting" and then the magazine presetting is
executed on start and first pass.