Maintenance and Service
9
Cleaning the device
Use a soft cloth moistened either with water or a mild cleaning agent to clean the housing,
display and operator control elements of the HT8.
Checking the device
In order to prevent foreign bodies or liquids entering the HT8, regularly check the device
that all the housing screws are in place and tight
for damage to the housing
for damage to the cable cover or cable entry
Protect the device from environmental e󹪜ects
Protect the HT8 against
direct solar radiation and heat sources
mechanical vibration and shock
dust
moisture, and
strong magnetic 󹪝elds
Checking the emergency stop button and the enabling button
Check the emergency stop button regularly to ensure that it functions correctly.
Check the enabling button regularly to ensure that it functions correctly in the enable and
panic position.
WARNING
Danger of death caused by damaged HT 8
Immediately check the functioning of the emergency stop button and the enabling button if
the device was subject to signi󹪝cant shock (e.g. because it was dropped).
Handheld Terminal HT 8
Equipment Manual, 02/2024, A5E52918633B AA 129

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals