• The computer to be monitored must be congured in the cong.ini conguration le of the
TCU according to the general conguration for a TCU in a separate host section as a
switchover target for this TCU.
Where necessary, a password has to be specied in the conguration, if the VNC server
requires one on the target system (see below).
• To ensure that the TCU recognizes the new switchover target, the TCU requires a restart and
reboot.
• The screen resolution of the computer to be monitored must be adjusted to the conditions
of the TCU, since otherwise the TCU scales the image received to its possible range of
representation, which would adversely aect the representation on the TCU.
Conguration
1&8
7&8
6\VWHPQHWZRUN
1HWZRUN
3*3&
;
;
Figure4-21 Conguration example
Conguration
The cong.ini le is located in the following directory:
NCU: /user/common/tcu/<TCU name>/common/tcu
PCU (WindowsXP): F:\user_base\common\tcu\<TCU name>\common\tcu
PCU (Windows7): C:\ProgramData\Siemens\MotionControl\user\common\t
cu\<TCU name>\common\tcu
The cong.ini le must be stored on the boot server (active DHCP).
Example:
[Station]
General information and networking
4.3Networking
Handheld Terminal HT 8