EasyManuals Logo

Siemens SIPART PS2 6DR5010 Series User Manual

Siemens SIPART PS2 6DR5010 Series
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
3
SIP ART PS2 Manual
A5E00074631--01
Contents
0 Information for the Operator 5.............................................
0.1 General information 5...........................................
0.2 Meaning of safety instructions and warnings 6.....................
0.3 Qualified Personnel 7...........................................
0.4 Use as intended 8..............................................
0.5 Technical Documentation 8......................................
0.6 W arranty Information 9..........................................
0.7 Delivery Notes 9...............................................
0.8 Standards and Regulations 10....................................
1 Introduction 11............................................................
1.1 General information about the positioner 11.........................
2 Design and Method of Operation 15........................................
2.1 Overview 15....................................................
2.2 Instrument Components 16.......................................
2.2.1 Motherboard 17.................................................
2.2.2 Electrical Connections 17.........................................
2.2.3 Pneumatic Connections 18.......................................
2.2.4 Mounting Kit 21.................................................
2.2.5 Purge air switching (not in the explosion proof version) 21............
2.2.6 Restrictors 21...................................................
2.3 Method of Operation 22..........................................
2.4 State as supplied 25.............................................
2.5 Options modules 25.............................................
2.5.1 Options modules in normal and intrinsically safe versions 25..........
2.5.2 Options modules in explosion proof version 28......................
2.5.3 HART-function 29...............................................
2.5.4 Alarm module 30................................................
2.5.5 Jy-module 31...................................................
2.5.6 SIA module 31..................................................
2.5.7 Accessories 32.................................................
3 Preparing for Operation 33.................................................
3.1 Instrument identification (type key) 33..............................
3.2 Dimensional drawings 33.........................................
3.3 Assembly 35....................................................
3.3.1 Instructions for using positioners in a wet environment 36.............
3.3.2 Instructions for using positioners which are exposed to great accelerations
or vibrations 38.................................................
3.3.3 Mounting kit linear actuator” 6DR4004-8V and 6DR4004-8L 39.......
3.3.4 Assembly procedure (see figure 3-6, page 41) 39....................

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPART PS2 6DR5010 Series and is the answer not in the manual?

Siemens SIPART PS2 6DR5010 Series Specifications

General IconGeneral
Enclosure RatingIP66/NEMA 4X
Communication ProtocolHART
Housing MaterialAluminum or stainless steel
TypeElectropneumatic
Input Signal4-20 mA
Supply Pressure1.4 to 7 bar
Stroke Range3 to 130 mm
Temperature Range-40°C to +80°C
Ambient Temperature Range-40°C to +80°C
MountingLinear or rotary actuators
Power Supply4-20 mA loop powered

Related product manuals