Details the classification of safety notices (DANGER, WARNING, CAUTION, NOTICE) and their meanings.
Defines qualified personnel and their responsibilities for installation, configuration, and operation.
Provides an overview of the positioner's control system, setpoint, actual value, and control logic.
Explains the operational method, including the control circuit, setpoint, actual value, and control algorithm.
Details the procedure for installing option modules in normal and intrinsically safe versions of the positioner.
Provides instructions for installing option modules in explosion-proof versions of the positioner.
Outlines the general assembly procedure and safety warnings for installing the positioner and mounting kit.
Lists the scope of delivery for the mounting kit used for linear actuators (6DR4004-8V and 6DR4004-8L).
Details the scope of delivery for the mounting kit used for part-turn actuators (6DR4004-8D).
Details specific warnings and requirements for electrical connections in hazardous areas.
Explains the two-wire connection for non-intrinsically safe and explosion-proof versions.
Provides instructions for connecting the positioner in intrinsically safe circuits.
Details the electrical connection for versions with type of protection 'n'.
Introduces the commissioning process, including parameterization and available initialization methods.
Details preparations for linear actuators, including transmission ratio selector and initial lever positioning.
Explains the steps for automatic initialization of linear actuators, including display indications.
Describes the manual initialization procedure for linear actuators, allowing manual setting of start and end positions.
Covers preparations for part-turn actuators, including transmission ratio selector setting.
Explains the steps for automatic initialization of part-turn actuators.
Describes the manual initialization procedure for part-turn actuators.
Explains how to copy initialization data from one positioner to another, useful for device replacement.
Outlines the five operating modes: P-manual, Configuration, Manual, Automatic, and Diagnostic.
Explains the Manual (MAN), Automatic (AUT), and Diagnostic display operating modes.
Lists all positioner parameters, showing their names, functions, values, units, and factory settings.
Explains the YFCT parameter for matching the positioner to the actuator type and sensor.
Describes setpoint characteristic definition and valve linearization using SFCT parameter.
Details the alarm function, its parameters (AFCT), and adapting digital output actions.
Explains parameters for alarm thresholds (A1, A2) and the setup of extended diagnostics (XDIAG).
Details the activation and configuration of extended diagnostics modes (On1, On2, On3) via parameter XDIAG.
Explains parameters for configuring the partial stroke test, including start position, tolerance, step height, direction, and interval.
Provides a guide to fault correction based on operating mode, environment, and fault occurrence timing.