2
DEVICE DESCRIPTION
12
SITRANS FX330
www.siemens.com/flow 09/2018 - A5E40861058-AB
Max. permissible product and ambient temperatures with signal converter or
connection box mounted at side or underneath the flow sensor
Temperature class in °C
Temperature class in °F
Temperature class T6 T5 T4 T3 T2
T
amb
in °C 60 65 60 65 60 65 40 60 65 40 60 65
Nominal size
DN1525 85 65 100 100 135 135 200 200 200 1 240 240 240 1
DN4050 80 65 100 100 135 135 200 200 200 1 240 240 240 1
DN65100 85 65 100 100 135 135 1 200 200 1 200 1 240 240 1 240 1
DN150...300 80 65 100 100 135 135 200 200 200 1 240 240 240 1
1 Permanent service temperature of connecting cable and cable entry min. 80°C
Temperature class T6 T5 T4 T3 T2
T
amb
in °F 140 149 140 149 140 149 104 140 149 104 140 149
Nominal size
DN1525 185 149 212 212 275 275 392 392 392 1 464 464 464 1
DN4050 176 149 212 212 275 275 392 392 392 1 464 464 464 1
DN65100 185 149 212 212 275 275 1 392 392 1 392 1 464 464 1 464 1
DN150...300 176 149 212 212 275 275 392 392 392 1 464 464 464 1
1 Permanent service temperature of connecting cable and cable entry min. 176°F