Technical data
SITRANS LC300
34 Operating Instructions, 05/2021, A5E47904073-AA
Weight
• Depends on configuration.
Process
See SITRANS LC300 Pressure versus temperature curves (Page 51).
Not recommended for direct steam contact
1)
-1 to 35 bar g (-14.6 to 511 psi g)
Without temperature extended shaft:
-40 to 85°C (-40 to 185°F)
-20 to 85°C (-4 to +185°F) with option FFKM seal O-ring
With temperature extended shaft:
-40 to 200°C (-40 to 392°F)
-20 to 200°C (-4 to +392°F) with option FFKM seal O-ring
With ATEX approval:
Depending on Surface Temperature and Temperature Class, refer to
Flameproof / explosion proof configuration in hazardous areas
Min. relative dielectric constant (εr)1.5
1)
See SITRANS LC300 Pressure versus temperature curves (Page 51).
Approvals
2)
CSA/FM Class II, Div. 1, Gr. E, F, G, Class III
Flame Proof / Explosion Proof
CSA/FM Class I, DIv. 1, Gr. A, B, C, D
Lloyd's Register of Shipping, Categories ENV1, ENV2 and ENV5
ABS Type Approval
2)
Please verify against device nameplate.