Technical data
SITRANS LC300
34 Operating Instructions, 05/2021, A5E47904073-AA
Weight
Depends on configuration.
Process
Note
See SITRANS LC300 Pressure versus temperature curves (Page 51).
Not recommended for direct steam contact
Pressure range
1)
-1 to 35 bar g (-14.6 to 511 psi g)
Temperature range
Without temperature extended shaft:
-40 to 85°C (-40 to 185°F)
-20 to 85°C (-4 to +185°F) with option FFKM seal O-ring
With temperature extended shaft:
-40 to 200°C (-40 to 392°F)
-20 to 200°C (-4 to +392°F) with option FFKM seal O-ring
With ATEX approval:
Depending on Surface Temperature and Temperature Class, refer to
Flameproof / explosion proof configuration in hazardous areas
(Page 19).
Min. relative dielectric constant (εr)1.5
1)
See SITRANS LC300 Pressure versus temperature curves (Page 51).
Approvals
2)
General
CSA, FM, CE
Hazardous
Dust Ignition Proof
ATEX II 1/2D, IIIC
CSA/FM Class II, Div. 1, Gr. E, F, G, Class III
INMETRO
Flame Proof / Explosion Proof
ATEX II 1/2G, IIC
CSA/FM Class I, DIv. 1, Gr. A, B, C, D
INMETRO
Marine
Lloyd's Register of Shipping, Categories ENV1, ENV2 and ENV5
ABS Type Approval
Overfill Protection
AIB-Vincotte
2)
Please verify against device nameplate.