1.4 Checking the consignment
1. Check the packaging and the device for visible damage caused by inappropriate handling during shipping.
2. Report any claims for damages immediately to the shipping company.
3. Retain damaged parts for clarification.
4. Check the scope of delivery by comparing your order to the shipping documents for correctness and completeness.
WARNING
Using a damaged or incomplete device
Danger of explosion in hazardous areas.
Do not use damaged or incomplete devices.
1.5 Nameplate layout
Nameplate with general information
The nameplate bearing the Order No. and other important information, such as design details and technical data, is on the
side of the enclosure.
F illing
Silik onöl
Mat.: Connec. Diaphr.
V :DC1 0.5-45 V (not intr.s ave) outp.:4-20 mA
H
Measuring span
Ove rrange limits
Type of protection IP 65
Fab. Nr. N1LN1 1-0 04711
Tr ansmit ter fo r pressur e
1.4404 2.481 9
7MF4033-1EB1 0-1D A1
: 0.6 3 - 6 3 bar
:-1-100bar
Made in Fr ance
0032
PED:SEP
SITRANS P
D-76181 Karlsruhe
Order number (machine-readable product code) Serial number
Figure 1-1 Example of a nameplate
Nameplate with approval information
On the opposite side is the nameplate with approval information. This nameplate shows e.g. the hardware and firmware
versions. Certificate information is also listed if the transmitter is an ex-version.

Table of Contents

Other manuals for Siemens SITRANS P series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SITRANS P series and is the answer not in the manual?

Siemens SITRANS P series Specifications

General IconGeneral
CommunicationHART, PROFIBUS PA, FOUNDATION Fieldbus
Housing MaterialStainless steel, aluminum
Measurement RangeVaries by model (e.g., 0-10 bar, 0-100 bar, etc.)
Output4-20 mA, HART, PROFIBUS PA, Foundation Fieldbus
Operating Temperature-40°C to +85°C (-40°F to +185°F)
Ingress ProtectionIP66, IP67
Measured MediumLiquids, gases
Process Temperature-40°C to +125°C (-40°F to +257°F)
Ambient Temperature-40°C to +85°C (-40°F to +185°F)
ApprovalsATEX, IECEx, CSA
Process Connection1/2" NPT