Technical data
5.1 Specifications
Transducers
38 Compact Operating Instructions, 01/2018, A5E43390688_AA
Enclosure
• PVDF Co-
polymer
• CSM
• Option:
Flange with
PTFE fac-
ing
• ETFE
• Option:
PVDF
• PVDF
• Option: foam facing
• Flange with PTFE facing
Thread size R 1" [(BSPT),
EN 10226]
1" NP
1" and 2" NPT
R 2" [(BSPT),
EN 10226]
2" [(BSPP), EN
R 1" [(BSPT),EN 10226]
1" NPT
R 1.5" [(BSPT),
EN 10226]
Universal
thread
Colour Blue White Blue Standard:
Blue
XPS-15F:
Blue
Cable Type 2-wire shield-
ed/twisted, 0.5
mm
2
(18 AWG)
PVC jacket
2-core shield-
ed/twisted,
0.519 mm
2
(20
AWG),PVC
2-wire shielded / twisted, 0.5 mm
2
(20 AWG) PVC jacket
Max. separa-
tion from
365 m (1200 ft) from transducer
Ingress Protec-
IP65/IP68 IP68 IP66/IP68
2)
Options Factory flange
to suit ANSI,
DIN, or JIS
standard
Submergence
shield, where
flooding can
occur Split
flange for field
mounting to
suit ANSI, DIN,
Flange adapt-
er, refer to
associated
instructions
Factory flange to suit ANSI
standard
Submergence shield, where
flooding can occur
Factory flange
to suit ANSI
standard
For approvals information refer to Appendix B: Certificates. (Page 53)
1)
Application conditions such as extreme dust or angle of repose may reduce the usable
maximum range. Consult a local sales person for more details.
2)
Approximate shipping weight of transducer with standard cable length