Technical specifications
SCALANCE X-200
74 Operating Instructions, 03/2015, C79000-G8976-C284-06
Permitted ambient conditions
Note
Note the mounting position for XF and TS devices
With the following switches an ambient temperature of maximum +40 °C is permitted if the
device is installed on a vertical rail:
XF204
XF208
XF204-2
XF206-1
XF204IRT
X204-2TS
X204-2LD TS
Type
Operating temperature
Storage/transport temper-
ature
Rel. humidity in
operation (no con-
densation)
Operating altitude at max. xx
°C ambient temperature
X204-2
-40 °C to +60 -40 °C to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
X204-2TS
-40 °C to +70
*)
-40 °C to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
X204-2FM
-40 °C to +60 -40 °C to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
X204-2LD
-40 °C to +60 -40 °C to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
X204-2LD TS
-40 °C to +70 °C
*)
-40 °C to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
X206-1
-40 °C to +60 -40 to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
X206-1LD
-40 °C to +60 -40 °C to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
X208
-40 °C to +60 °C -40 to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
X208PRO
-40 to +70 -40 to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
X212-2
-40 °C to +60 -40 °C to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
X212-2LD
-40 °C to +60 -40 to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
X216
-40 to +60 -40 to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
X224
-40 to +60 -40 to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
XF204 *)
-40 °C to +60 °C -40 to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
XF204-2
-40 °C to +60
*)
-40 °C to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50
XF206-1
-40 °C to +60
*)
-40 °C to +70 ‹ 95 % 2000 m at max. 56
3000 m at max. 50