Page 2 XPS 10/15 F Series Transducer A5E32725813
Specifications
Specifications
XPS 10 F Series Transducers
Measurement Range:
0.3 – 10m (1 – 33ft)
Frequency:
43kHz
Beam Angle:
12°
Environmental
location: indoor/outdoor
altitude: 2000m maximum
ambient temperature: -20 to 95°C (-4 to 203°F)
pollution degree: 4
Construction
exposure: Kynar
®1
colour: slate gray
mounting: 1” NPT conduit connection
options: factory flange to suit ANSI standard
submergence shield, where flooding can occur
split flange for field mounting to suit ANSI
cable: 2-wire shielded / twisted, 0.5 mm
2
(20 AWG) PVC
jacket
Supply Source
Transducer shall only be supplied by a Siemens certified controller.
Weight
2
0.8kg (1.8lb)
Separation
365m (1200ft) from transducer
Approvals
FM Class 1 Div 1, Group A, B, C and D
FM Class 2 Div 1, Group E, F, and G
see nameplate or consult Siemens for other current approvals
1
Kynar
®
is registered trade mark of ELF Atochem.
2
approximate shipping weight of transducer with standard cable length