A5E32725813 XPS 10/15 F Series Transducer Page 3
Specifications
XPS 15 F Series Transducers
Measurement Range:
0.45 – 15m (1.5 – 50ft)
Frequency:
43kHz
Beam Angle:
Environmental
location: indoor/outdoor
altitude: 2000m maximum
ambient temperature: -20 to 95°C (-4 to 203°F)
pollution degree: 4
Construction
exposure: Kynar
®3
colour: slate gray
mounting: 1” NPT conduit connection
options: factory flange to suit ANSI standard
submergence shield, where flooding can occur
split flange for field mounting to suit ANSI
cable: 2-wire shielded / twisted, 0.5 mm
2
(20 AWG) PVC
jacket
Supply Source
Transducer shall only be supplied by a Siemens certified controller.
Weight
4
2.0 kg (4.4lb)
Separation
365m (1200ft) from transducer
Approvals
FM Class 1 Div 1, Group A, B, C and D
FM Class 2 Div 1, Group E, F, and G
see nameplate or consult Siemens for other current approvals
3
Kynar
®
is registered trade mark of ELF Atochem
4
approximate shipping weight of transducer with standard cable length