30 I EOX
®
Assembly
#1
#2
6.2 EOX
®
Ribbon Butler
Insert EW-EN100 in Ribbon Butler
Loosen the clamping
screw (2.5 mm Allen
key)
Open the clamp
Loosen the four screws
of the back case cover
(Phillips-head screw)
Open the back
case cover
Connect the cable from motor side to port #1 of
EW-EN100.
Optionally, connect another SHIMANO component
(e.g. shifter) EW-EN100 to port #2 of EW-EN100.