Operating manual - English MARKER 2000
Copyright Silca 2002 43
Replacing the X axis sensor
1) turn off the master switch and remove the plug.
2) remove the cover (Q) (ch.9.4) and place next to the machine, without disconnecting the display
connector.
3) disconnect the connector (X3) (fig. 42) (cut the wire tie securing it to the metal plate).
4) loosen nut (X4), unscrew the sensor and remove.
5) place the new sensor in position and screw down until it almost contacts the plate (maintain a distance
of approximately 0,4 mm) and secure with the nut (X4).
6) connect the X sensor connector (8) to the wire and secure to the metal plate with a wire tie.
7) connect the marking machine and proceed with “SETTING THE ZEROES” (ch.7).