Usermanual Motors 902x_903x Page 17
7 Programming and Operating of
SG 9022/9023 and SG 9032/9033
These motors and Electric Curtain Track Systems are equipped with
a Manual Override function, i.e. the curtain can be moved by hand if
the motor is turned off. This function is only applicable with a low volta-
ge switching.. In addition, no intermediate position can be programmed.
The programming occurs through following steps
To do Signal
Step
1
2
3
Check if the DIP switch setting is correct
(Setting according to Chapter 5.8).
Disconnect power supply of the motor for 5
seconds and make sure that the motor will
have permanent power supply when
reconnected. Typically unplug power
lead from motor.
Pull the curtain to about the middle position
between the two end positions.
5
6
7
Reconnect to power supply and
simultaneously push programming
button 1 or 2.
Move the curtain to one end position.
Motor is programmed.
Acoustic Signal,
LED lights
Motor stops
automatically
4 Simultaneously press both buttons (1&2)
and hold depressed for > 6 seconds.
After 3 seconds motor will sound and the
light will flash. Do not release the buttons.
Wait until motor sounds and light flashes
for the second time. Motor is then in pro-
gramming mode for 3 minutes.
Acoustic Signal
and LED blinks
after 3 and 6 seconds
respectively