30errorNX2.doc Page 2 Latest update: 18 Nov -02
No. Message and cause * Remedy
23 DGPS (RTCM) data ignored. ¤ Change the DGPS (RTCM) setting.
24 GPS bad fix, no fix position (time
expired at one-fix).
¤ Check GPS antenna location.
25 No autopilot response. Object is not
connected.
Check wiring connections and fuse.
26 The unit is not allowed to power up
because there is too high input
voltage.
* Check input voltage.
27 Extended object server busy or error. Set one GPS Navigator instrument to master.
28 Route command error. The
waypoint bank memory is full.
Clear waypoint bank for new space.
29 DGPS mode is interrupted. ¤ Check the DGPS receiver.
30-
41
Reserved for NEXUS Autopilot
Servo Unit.
See NEXUS Autopilot manual.
42 Bad transducer input / bad
measurement.
* Reset power.
Reserved for NEXUS Autopilot
Servo Unit.
30 General autopilot failure * Reset power.
31 Autopilot compass input failure in
autopilot standalone connection.
Check compass connection at autopilot Servo
Unit.
32 Autopilot compass input failure in
autopilot NEXUS Network connection.
Check compass at NEXUS Server or at the
Compass Data instrument
33 Received wind data input failure. Check wind wire connection.
34 Autopilot calibration failure. Check for air in the system and make APC
routine again in calm water at crousing speed.
35 Navigation data not available in
autopilot stand alone connection.
Check NMEA input connections and settings
in the navigator.
36 Navigation data not available in
autopilot NEXUS Network connection.
Check connections and navigator settings.
37 Autopilot Network re-initialisation. Check connections, wire dimensions and
Battery charge and quality.
38 Autopilot Rudder transmitter failure * Check Rudder transmitter, connection and
wireing.
41 Failure to initialise EEPROM. * Reset power.