1.2 Preliminary checks
a
WARNING
Should it be necessary to access the areas in the
bottom part of the appliance, make sure that the
system components and pipes are not hot (risk of
burning).
Before replenishing the heating system, put on
protective gloves.
Prior to use the
GIULIA COMBI
boiler must be installed and
commissioned by a Gas Safe Registered engineer. It may be
necessary for the user to occasionally have to start the boiler,
for instance after a holiday or after an interruption of the gas
supply. In these cases the following operations must be car-
ried out.
check that the gas isolation and water system valves are
open
using the pressure gauge (1) check that the pressure in the
heating system, when cold, is
1-1.2 bar
. If the pressure is
less than this, use the external filling device to repressurise
the system to
1-1.2 bar
ensure that the filling device is turned off after use.
1
Fig. 2
1.3 Ignition
After having carried out the preliminary checks, proceed as
follows:
set the main system switch to "ON"
ON
Fig. 3
on the display, check that the operating mode on the dis-
play is "SUMMER”
l
and if necessary select it by pressing
and holding the button
s
for at least 1 second. The internal
temperature of the boiler will appear on the display
open one or more than one hot water tap. The
r
should ap-
pear on the display and the boiler will ignite and stay alight
until the tap is turned off.
Once the boiler has been operated in "SUMMER mode"
l
"WINTER mode"
n
can be selected by pressing and holding
the button
s
for at least 1 second. The internal temperature
of the boiler will appear on the display. Ensure that any timers
and room thermostats are in the on position. The
t
will ap-
pear on the display and the boiler will ignite.
1.4 Adjusting the delivery temperature
Should you wish to increase or decrease the boiler delivery
temperature, turn the dial
t
to the desired setpoint. The val-
ue can be set to between 20°C and 80°C.
Fig. 4
1.5 Adjusting the domestic hot water tem-
perature
Should you wish to increase or decrease the domestic hot wa-
ter temperature, turn the dial
r
to the desired setpoint. The
value can be set to between 10°C and 60°C.
Fig. 5