Press and hold both the MENU and MODE buttons for 5 seconds to enter the
Advanced Menu.
Press DOWN until >HVAC INFO is shown.
Press MODE to enter the HVAC conguration menu.
The following settings are available:
HVAC TYPE HEAT COOL
HEAT ONLY
COOL ONLY
HT PUMP
HT PUMP EMR
Type of system connected to this
thermostat.
When connected to Wi-Fi, these settings
are congured via the app.
CHANGEOVER O – COOL ON
B – HEAT ON
Applies only to heat pumps. Determines
whether heat or cool is active. Most heat
pumps are O, but Rheem/Ruud typically
use B.
If your heat pump is heating when it
should be cooling, and vice-versa, please
change this setting.
FURNACE GAS
ELECTRIC
Applies only to forced air systems,
including heat pump emergency heat.
Step 2: Enter System Conguration