YOUR SAFETY AND THE SAFETY OF THOSE AROUND YOU ALWAYS COMES FIRST.
Actions taken during a fire depend upon local practices. Be sure you know what to do.
ALARM TROUBLE / SUPERVISORY
RED LED IS FLASHING AND TONE-ALERT IS PULSING
FIRE = 3 SUPERVISORY = 0 TROUBLE = 0
FIRE ZONES: 02 07 06
FIRE
ALARM
ALARM
ACK
SYSTEM
SUPERVISORY
SYSTEM
TROUBLE
ALARM
SILENCED
AC
POWER
SUPV
ACK
TROUBLE
ACK
ALARM
SILENCE
SYSTEM
RESET
Menu
Function
Disable
Enable
Exit
Clear
Enter
Previous
Next
RED ALARM LED
(FLASHING)
ALARM
ACKNOWLEDGE
KEY
ALARM
SILENCE
KEY
SYSTEM
RESET
KEY
ALPHA-
NUMERIC
DISPLAY
ALARM
SILENCED
LED
1. Unlock and open the panel door. Read and follow the instructions
on the display. It will toggle between Screens 1 and 2.
SCREEN 1
SCREEN 2
2. Press the (ALARM ACK) key under the flashing red LED. Read the
alphanumeric display.
The tone-alert is silenced and the display shows pertinent
report information, such as shown below.
SCREEN 3
3. Read the Alarm information on the display. Summon appropriate
personnel to respond.
HOW TO SILENCE THE SIGNALS
4. Press the (ALARM SILENCE) key and read the display. The
alphanumeric display shows signal status.
ALARM SILENCED LED turns ON steady.
HOW TO RESET THE SYSTEM
5. When the alarm condition clears, restore or replace all affected
devices (smoke detectors, pull stations, etc.) in accordance with the
instructions provided with each device.
6. Reset the system.
Press the (SYSTEM RESET) key.
The system displays the following after a completed System
Reset with no alarms present:
7. Press any key to return to the SYSTEM NORMAL screen.
YELLOW LED IS FLASHING AND TONE-ALERT IS ON STEADY
FIRE = 0 SUPERVISORY = 0 TROUBLE = 3
** TROUBLE ** Press ACK to review
FIRE
ALARM
ALARM
ACK
SYSTEM
SUPERVISORY
SYSTEM
TROUBLE
ALARM
SILENCED
AC
POWER
SUPV
ACK
TROUBLE
ACK
ALARM
SILENCE
SYSTEM
RESET
Menu
Function
Disable
Enable
Exit
Clear
Enter
Previous
Next
ALPHA-
NUMERIC
DISPLAY
LED (FLASHING)
YELLOW
TROUBLE
TROUBLE
ACKNOWLEDGE
KEY
Note: A Trouble Condition is described in this example. A
Supervisory Condition is handled in a similar
manner.
1. Unlock and open panel door. Read and follow the instructions
on the display (see example below).
2. Press the (TROUBLE ACK) key under the flashing yellow LED.
Read the Trouble information on the display (see example
below).
3. Summon appropriate personnel to respond.
4. Response personnel should restore or replace the defective
device (switch, wire, notification appliance, etc.) in accordance
with device instructions.
If necessary, press (SYSTEM RESET) when the
abnormal condition has been corrected.
After a short delay, the system returns to normal and
displays the following.
Note: If your system configuration does not match this sheet,
consult Simplex for specific operations. Simplex is
listed in the Yellow Pages.
In case of trouble, notify:
Name
Address
Phone#
THESE INSTRUCTIONS ARE INTENDED TO BE FRAMED AND MOUNTED ADJACENT TO THE
CONTROL PANEL FOR READY REFERENCE.
See Operator’s Instruction Manual for detailed operation.