EasyManuals Logo

Simplex 4100U Manual

Simplex 4100U
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
3 S4100-0035-2 5/02
ALARMFIRE
PULL DOWN
ALARMFIRE
PULL DOWN
ALARMFIRE
PULL DOWN
ALARMFIRE
PULL DOWN
ALARMFIRE
PULL DOWN
ALARMFIRE
PULL DOWN
Second floor
Third floor
Fourth floor
Fifth floor
Sixth floor
Seventh floor
First floor
4100U Fire Alarm Control Panel
with Voice Control
MINIPLEX transponder
Speaker NAC
TrueAlarm sensors
and IDNet/MAPNET II
addressable circuits
Audio riser wiring,
twisted pair
RUI communications
wiring, twisted, shielded
pair
Legend:
ALARMFIRE
PULL DOWN
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
Press ACK located under flashing indicator.
Repe a t o p e rat i on un t il all ev ent s ar e ac kn ow l e dg e d.
Local tone will silence.
A B C
AC Power
D E FG H I
J K L M N OP Q R
'SP' ( ), 0 :
S T U V W XY Z /
ALARMS
Fire Alarm Priority 2 Alarm
SYSTEM WARNINGS
Supervisory Trouble
Alarm Silenced
Emergency Operating Instructions
Alarm or Warning Condit ion
How to Acknowledge / View Events
How to Silence Building Signals
Syst em in d i cat or f l as hi ng . T on e On . Pre s s Al arm Sil ence.
How to Reset System
Press System Reset.
Press Ack to silence tone device.
ZONE
1
SIG
2
AUX
3
FB
4
IO
5
IDNet
6
P
7
A
8
L
9
NET ADDR
0
DEL
Enter C/ Ex it
Fire Alarm
Ack
Priority 2
Ack
Supv
Ack
Trouble
Ack
Alarm
Silence
System
Reset
Event
Time
Enable
On
Arm
Disable
Off
Disarm
Auto
Lamp
Test
More
Info
Menu
Previous
Next
SYSTEM IS NORM AL
08:23:43 am MON 11-DEC-00
Fire Control
C
A
U
T
I
O
N
C
A
U
T
I
O
N
DISCONNECT
A.C. POWER
AND
BATTERY
BEFORE
SERVICING
DISCONNECT
A.C. POWER
AND
BATTERY
BEFORE
SERVICING
C
A
U
T
I
O
N
C
A
U
T
I
O
N
DISCONNECT
A.C. POWER
AND
BATTERY
BEFORE
SERVICING
DISCONNECT
A.C. POWER
AND
BATTERY
BEFORE
SERVICING
MINIPLEX transponder
Strobe NAC
Subject Data Sheet Subject Data Sheet
Enclosures S4100-0037 Basic Panel Modules and Accessories S4100-0031
LED/Switch Modules S4100-0032 Network Display Unit (NDU) S4100-0036
4100U Audio/Phone Modules S4100-0034 Remote Annunciators S4100-0038
TrueAlert Addressable Products S4009-0003 Remote Battery Charger S4081-0002
Typical Multi-Floor MINIPLEX Audio System
Additional 4100U Data Sheet Reference

Other manuals for Simplex 4100U

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simplex 4100U and is the answer not in the manual?

Simplex 4100U Specifications

General IconGeneral
Control Panel TypeAddressable Fire Alarm Control Panel
DisplayLCD
Power Supply120/240 VAC, 50/60 Hz
Max Signaling Line Circuits (SLC)2
Operating Temperature0°C to 49°C (32°F to 120°F)
Humidity Range10% to 93% non-condensing
Network CapabilityYes
Communication ProtocolRS-232, RS-485
Battery Backup24 VDC
NAC Outputs4
Signaling Line Circuits (SLCs)2
Power Supply Current3.0 A
Max Notification Appliance Circuits (NAC)4
Max Releasing Circuits4
Max Relay Circuits4
Communication PortsRS-232, RS-485

Related product manuals