Operating
Instructions
=
ж
=
=
==:
2.5
V.A.C.
RANGE
INAC-
RANGE
==
——
=
50
V.A.C.
RANGE
Percent
Relative
Frror
Frequency
FREQUENCY
RESPONSE
FOR
OUTPUT
MEASUREMENTS
The
Model
270
Series
2
has
a
capacitor
in
series
with
the
OUTPUT
jack.
This
blocks
the
D.C.
component
of
the
cur-
rent
in
the
measuring
circuit,
but
allows
the
A.
C.,
or
desired
component,
to
pass
on
to
the
meter
circuit.
The
blocking
capacitor
placed
in
series
with
the
A.C.
voltage
measuring
circuits
alters
the
A.C.
response.
The
above
curves
show
the
frequency
response
of
the
2.5,
10,
and
50
volt
ranges.
l.
Set
the
function
switch
on
the
left
hand
side
of
the
front
panel
at
A.C.
2.
Connect
the
black
test
lead
in
the
COMMON-
jack
and
the
red
test
lead
in
the
OUTPUT
jack.