EasyManua.ls Logo

Simrad AP27 - IS15 Rudder

Simrad AP27
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical specifications
20221586B 137
8.11 IS15 Rudder
Dimensions: ............................... See Figure 8-11
Weight: ...................................... 225 grams
Environmental Protection:......... IP56 from front, IP44 from rear
Power requirement: .................. 12/24 VDC, 70 mA (100 mA max with max
lighting)
Safe distance to compass:.......... 0.15 m (0.5 ft.)
Temperature: Operating: ........ –0 to +55°C (+32 to +130°F)
Storage: ............................. –30 to +80°C (–22 to +176°F)
Scale: ......................................... Full deflection adjustable for any h.o. angle
between ±20° and ±45°. Divisions: Marking per
each 1/8 of full deflection. Accuracy: ±2° of full
scale deflection.
Heading Display (Digital): ........ 0 to 359°
Heading Resolution: ..................
Heading reference:..................... True or Magnetic North
Heading Lock: ........................... Course and direction to steer on digital display
Course to Steer: ......................... Settable on digital display
Display Backlighting:................ Green color with seven levels plus Off
Display Backlighting Control:... Two independent lighting banks or individual
settings (bank 0)
Inputs: Rudder Angle: ............ 2-wire p.w.m.
NMEA 0183, RSA
Roblink (IS15 system)
Compass heading: ...... NMEA 0183, HDG, HDM, HDT
Outputs: Rudder Angle:............ NMEA 0183, RSA, 5 Hz*
Compass heading: ...... NMEA 0183, HDG
Other:.......................... NMEA 0183 sentences according to IS15
NMEA in/out table.