CR40/42/50 MKII Installation manual Chapter 9
138
RB716A Open scanner
3 or 4ft Open array
4kW
Range up to 48nm
Rotation speed 24
or 48 (24V) rpm
Beamwidth:
Horizontal 2.5°, 1.8°
Vertical 22°
The bolts included with your radar
equipment will suffice for mount base
thickness of 9 to 14mm (0.35 to 0.55
in.). If the mount base is thicker or
thinner than this, prepare bolts as listed
on the previous page.
Silicone should be applied to secure the
bolts. Do not use locking putty, as it
may damage the radome.
Drilling template for RB716A.
Fi f
Double nuts
S
p
rin
g
washer
Washer
M12 Hexagonal bolt
Mount base
Scanner base
4 1346 mm (53.8)
3 1034 mm (41.4)
330 mm
13.2
450 mm
18
Fix four bolts