Step Procedure
7.Remove evaporator assy
a
b
c
d
Remove 3 screws xing evaporator assy.
At the back of the unit, Loosen the clasp,connection
pipe clamp and then remove the connection pipe
clamp.
First remove the left side of evaporator from the groove
of bottom shell and then remove the right side from the
clasp on the bottom shell.
Adjust the position of connection pipe on evaporator
slightly and then lift the evaporator upwards to remove
it.
Screw
Connection pipe clamp
Clasp
Groove
Rear Case assy
Evaporator assy