21
3.7.11 Filter Clean Reminder Setting
After entering user function page, press
or
button to select
clean function option and press
or
button to turn on or turn off
this function. Press MENU button to enter the setting page of filter clean
reminder function.
After entering the setting page of filter clean reminder function, press
or
button to select pollution level and then press
or
button to set pollution level; press
or
button to select
accumulating time setting and then press
or
button to set
required time. After setting, press MENU button to save the setting.
When level 1 is selected, the adjusting range of accumulating
operating time is 5500~10000 hours, with 500 hours in each increase or
decrease.
When level 2 is selected, the adjusting range of accumulating
operating time is 1400~5000 hours, with 400 hours in each increase or
decrease.
When level 3 is selected, the adjusting range of accumulating
operating time is 100~1000 hours, with 100 hours in each increase or