EasyManua.ls Logo

Sinoboom GTJZ0608 - Electrical, Stability, and Load Safety

Sinoboom GTJZ0608
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hazard of Electric Shock
The machine is not insulated and does not have
electric shock protection.
Maintain a safe distance from the power line and
equipment according to the applicable
government regulations and the following table.
Voltage Minimum Safe
Phase to Phase Distance
0V-50kV 3.05 m
50kV-200 kV
4.60 m
200kV-350 kV 6.10 m
350 kV-500 kV 7.62 m
500 kV-750 kV 10.67 m
750 kV-1000 kV 13.72 m
Be wary of strong winds or gusts in view of
platform movement, electric wire wiggling or
drooping. Do not operate the machine when
there is lightning or heavy rain.
Stay away from the machine if the machine
comes into contact with a live wire. The person
on
the ground or platform must not touch or
operate the machine before the power is cut off.
Do not use the machine as ground electrode
during welding operation.
Hazard of Tip-over
The personnel, equipment and materials on the
platform should not exceed the maximum
carrying capacity of the platform.
GTJZ0608
Maximum bearing capacity of platform
Retraction of platform
380kg
Extension of platform - only
limited to platform
260kg
Extension of platform - only
limited to extension part
120kg
GTJZ0808
Maximum bearing capacity of platform
Retraction of platform
250kg
Extension of platform - only
limited to platform
130kg
Extension of platform - only
limited to extension part
120kg
8
GTJZ0608 & GTJZ0808 & GTJZ1012 & GTJZ1212 & GTJZ0612 & GTJZ0812 Operation Manual