30
TROUBLESHOOTING….cont
Problem Possible cause Possible solution
Table saw vibrates exces-
sively:
• Floor surface is uneven.
• V-belt is damaged.
• Saw blade is damaged.
• Loose bolt, Screws,
Nuts.
• Sit the saw on a level
surface.
• Replace the V-belt.
• Replace the Saw Blade.
• Tighten all Hardware.
Table saw does not start:
• Mains lead is not con-
nected to the mains
supply.
• Circuit fuse is blown.
• Circuit breaker has
tripped.
• Mains lead or Switch is
damaged.
• Connect the mains lead
to the electrical outlet.
• Replace circuit fuse.
• Reset circuit breaker.
• Have the Mains lead or
Switch checked, re-
paired or replaced.
Power Switch does not op-
erate:
• Power Switch contacts
are burned out.
• Capacitor is defective.
• Wiring connections are
loose or damaged.
• Have the Power Switch
checked, repaired or
replaced.
• Have the Capacitor
checked, repaired or
replaced.
• Have the wiring connec-
tions checked / re-
paired.
Fuses or circuit breakers
blow or open frequently:
• Motor is overloaded.
• Fuses or circuit breakers
are wrong size or defec-
tive.
• Dull saw blade.
• Power Switch or motor
is defective.
• Feed work-piece more
slowly.
• Replace fuses or circuit
breakers.
• Replace the saw blade.
• Have the Power Switch
or motor checked, re-
paired or replaced.
Table Saw is noisy when
running:
• Motor is loose or defec-
tive.
• Have the Motor
checked /repaired.
15
ASSEMBLY INSTRUCTIONS….cont
• Slide the 2 pipe clips (larger Ø) over the ends of the internal extraction hose.
• Fit the internal extraction hose from the back of the adaptor to the internal dust
collection cover.
Fitting the extraction assembly:
• Fit the extraction hose outlet adaptor to the rear panel of the saw stand by
means of:-
⇒ 4 x cross head M6 x 16 mm screws.
⇒ 8 x 6 mm washers.
⇒ 4 x M6 nuts.
Internal extraction hose
dust collection cover
Pipe clips
• Tighten the pipe clips to secure the extraction hose in place.
Extraction hose outlet adaptor
Note: The pictures show the saw the correct way up rather than upside
down.