tion, etc. or by using a virtual sensor (by manual or SMS command) to modify the irrigation units of all
the programs at the same time.
Optionally, one program currently irrigating can be temporarily suspended by sensor values, such
as wind, temperature, level, etc.
Optionally, complete monitoring for the instantaneous flow of irrigation meters is also available, with
programming of the planned flow in each sector and tolerances percentage based on excessive or de-
fault values. Detects lack of pulses or leakage.
FERTILIZATION
Number of fertilizers in separate tanks can be configurable from 0 to 4.
Pre and post irrigation values independent for each program.
Fertilization units measured by time (hh:mm) and, optionally (mm:ss); volume (L); or, optionally, by
hectare volume (L/ha).
Mixers use can be configured to be active or inactive, with pre-mixing and intermittent or continu-
ous mixing.
Fertilizers can be applied in three different ways:
In series: one type of fertilizer after another from a single injector.
Parallel: various fertilizers simultaneously with one injector per type.
Uniform (optional): applies and distributes each type of fertilizer uniformly between pre and post
irrigation. Applied in parallel.
Detection of the lack of pulses or water leakage is optional for volume sensors. Readings from each
meter are proportionally distributed to totals and records, according to the planned flow values for the
sectors that are related to that meter and that are being simultaneously fertilized.
PUMPING
There are 1 to 2 general irrigation outputs, or pumps, with activation sectors assignment and with
separate activation and deactivation temporizations. Temporizations are set to input and output for each
sector.
Optionally, a diesel engine or generator unit can also be controlled. Outputs for start-up, stop, con-
tact and preheating functions are available. Start-stop control of the electrical pump, as well as malfunc-
tions detection is also performed.
FILTER CLEANING
Configurable for 0 to 9 filters, with selectable cleaning time. Pause between filters is programmable.
Cleaning sequence may be started by the pressure differential and/or according to the time or vol-
ume of the water circulation.
Is it configurable to stop or not the irrigation sectors and fertilizers while the filters are being
cleaned.
Control over malfunctions due to continuous cleanings.
MANUAL
Manual commands can be used to start, stop, and remove irrigation programs from service, or
suspend them for certain times, sectors can be placed in manual or automatic mode, activate out of
service or general stop, start or stop filter cleaning, and finalize alarms and malfunctions. Optionally,
virtual sensors can be modified or outputs can be directly activated.
DETERMINING FACTORS
Optionally, the unit has a total of 30 completely configurable determining factors to trigger actions
that take into account certain conditions or values from digital or analog sensors and meters. There is a
wide variety of actions possible, such as the ability to make definitive, temporary or conditional stops
that are applied to specific programs or to all of them, start and/or stop irrigation, send a warning, adjust
irrigation or fertilizer units when starting an irrigation program according to an instantaneous value from
a sensor or the integrated value from a previous irrigation, etc. Moreover, each determining factor can
be configured to create a malfunction or send an SMS message to two private telephones and an SMS
message to another machine.