Opto outputs
Factory default value is NOT USED
Opto-isolated outputs can be set up to switch
when an event occurs in the EMES60 system.
Two opto output channels are provided.
Touch the box next to each opto channel to set
the event that causes it to trigger. Select “Not
Used” if no action is needed on that channel.
Two functions are selectable:
Pulses per NMset number of pulses is generated
per each nautical mile
Speed direction if speed is positive, the
optocoupler is open, if speed is negative, the
optocoupler is closed.
If Pulses per NM function is selected - touch the
next field to enter number of pulses, which will
be generated on the output per 1 nautical mile
Analog outputs
Factory default value is NOT USED
Analog outputs can be configured to provide a
varying voltage output in response to a measured
value in the EMES60 system.
Touch the first box to switch between 0 to 10 V
voltage output and 4 to 20 mA current output.
Touch the next button to select the value output.
The example shows a selection between
longitudinal speed, transverse speed, and the
resultant (vector sum) of the two speeds.