EasyManua.ls Logo

Skope VF650 - Troubleshooting

Skope VF650
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
SKOPE VF Series
Servicing
User Manual
Troubleshooting
For questions about the electronic controller, see page 11. For problems
with the cabinet and refrigeration cassette, use the following table.
Problem Possible Cause Suggestions
• Cabinet not
operating
• No controller display
• Loss of power
supply
• Check mains power supply.
• Interior light not on • Failed LED tube • Replace LED tube (see
page 13).
• Blown cabinet fuse • Contact an authorised
service agent to replace it.
• Power consumption
is higher than
expected
• Unit operating too
hot
• Clean the condenser coil
(see page 12).
• Ensure the cabinet has
good ventilation around the
refrigeration unit (see
page 5).
• Ensure the cabinet is in a
cool spot.
• Cabinet doors are
opened excessively
• Ensure doors are closed
more often.
• Product is too warm • Restricted airflow to
cabinet
• Ensure product is not
blocking airflow slots.
• Ensure there is space
around individual product
pieces.
• Warm cabinet
temperatures
• Compressor
operating for long
periods (more than 1
hour)
• Blocked condenser • Clean the condenser coil
(see page 12).
• Poor ventilation
around refrigeration
unit
• Ensure the cabinet has
good ventilation around the
refrigeration unit (see
page 5).