9
SKOPE VF Series
Operation
User Manual
Defrost To ensure efficient operation, the electronic controller forces a defrost cycle
when required. During a defrost cycle, the compressor stops, DEF and the
will display on the electronic controller faceplate. The freezer will resume
normal operation once the defrost cycle has finished. A manual defrost can
also be initiated by pressing and holding the
button.
Continuous
Cycle
The continuous cycle can be used to pull down the temperature of product
inside the freezer quickly. During a continuous cool down the compressor
runs continuously for a set time.
To start a continuous cycle
To stop a continuous cycle
Temperature
Setpoint
The VF Freezer Range is manufactured with a pre-set control temperature
set point of -21°C. If this set point does not match your required storage
temperature it is recommended that you change the set point accordingly.
The set point can be adjusted between -26°C and -16°C.
To view and adjust the temperature setpoint
1. While the freezer is switched on and
running, press and hold the and
buttons for five seconds.
The symbol will display during a
continuous cycle.
1. The electronic controller will
automatically stop the continuous cycle
after a period of time.
The continuous cycle can be stopped
by pressing and holding the and
buttons for five seconds.
1. To view the setpoint: press and hold the
key for 2 seconds, until the
setpoint value flashes
2. To adjust the setpoint: press either the
and keys to display the
required setpoint value.
3. Press the key again to memorise
the new setpoint value. If this is not
done within 60 seconds, changes will
be lost and you will need to repeat the
above procedure.