SJ40 T+, SJ45 T+ 238273AAA
Electrical System Section 4 – Troubleshooting Information
4.2-26 No Platform Level Up from the Base Console
1. Loose or broken wire #10A from IGN switch S5
to platform level switch S15
Check continuity. Replace if defective
2. Defective platform level switch S15 Check continuity through switch while activating up
function between wires #10A and #41B. Replace
switch if no continuity
3. Loose or broken wire #41B from platform level
switch S15 to base control module connector J2
pin 22
Check continuity. Replace if defective
4.2-27 No Platform Level Up from the Platform Console
1. Loose or broken wire #04 from platform terminal
block to platform level switch S19
Check continuity. Replace if defective
2. Defective platform level switch S19 Check continuity through switch while activating
platform level up function between wires #04 and
#41A. Replace switch if no continuity
3. Loose or broken wire #41A from platform level
switch S19 to platfrom control module connector
J12 pin 22
Check continuity. Replace if defective
4.2-28 No Platform Level Down from the Base or Platform Consoles
1. Loose or broken wire #40 from base control
module connector J2 pin 35 to turret harness
plug pin #14
Check continuity. Replace if defective
2. Loose or broken wire #40 from turret harness
plug pin #14 to platform level down valve 4H-40
Check continuity. Replace if defective
3. Loose or broken wire #02 from turret harness
plug to platform level down valve 4H-40
Check continuity. Replace if defective
4. Defective platform level down coil 4H-40 Check continuity and resistance through coil.
Replace if defective
4.2-29 No Platform Level Down from the Base Console
1. Loose or broken wire #10A from IGN switch S5
to platform level switch S16
Check continuity. Replace if defective
2. Defective platfrom level switch S16 Check continuity through switch while activating
platfrom level down function between wires #10A
and #40B. Replace switch if no continuity
3. Loose or broken wire #40B from platform level
switch S16 to base control module connector J3
pin 26
Check continuity. Replace if defective